Ariel Dynamics, Inc.
EMG MODULE
Revision 1.0
Contents
ARIEL
EMG PROGRAM
INTRODUCTION......................................................................................................................................
WHAT’S NEW IN EMG 1.0....................................................................................................................
SYSTEM REQUIREMENTS....................................................................................................................
SCREEN LAYOUT....................................................................................................................................
THE TOOL BAR.......................................................................................................................
THE EMG WINDOW LAYOUT.............................................................................................
THE STATUS BAR..................................................................................................................
TO START THE EMG PROGRAM........................................................................................................
CREATING A NEW EMG FILE..............................................................................................................
PARTITION...............................................................................................................................
GRAPH OPTIONS FOR EMG DATA FILE...........................................................................................
EMG............................................................................................................................................
AVG/RMS..................................................................................................................................
INTEGRAL.................................................................................................................................
POWER......................................................................................................................................
SAVING AN EMG FILE...........................................................................................................................
RESTORING PREVIOUSLY
CREATED EMG FILE...........................................................................
EMG OPTIONS.......................................................................................................................................
CHANGING THE FONT........................................................................................................
CHANGING EMG COLOR.....................................................................................................
EMG QUICK REFERENCE....................................................................................................................
EMG MENUS..........................................................................................................................................
FILE COMMAND MENU.....................................................................................................
EDIT COMMAND MENU....................................................................................................
VIEW COMMAND MENU...................................................................................................
GRAPH COMMAND MENU................................................................................................
EXPORT COMMAND MENU..............................................................................................
WINDOW COMMAND MENU...........................................................................................
OPTIONS COMMAND MENU............................................................................................
HELP COMMAND MENU....................................................................................................
One
of the most intriguing and challenging areas of study in biomechanics is
probably the muscle itself. The
electrical signal associated with the contraction of a muscle is called an
electromyogram or, by its shorthand name, EMG.
Electromyography is the study of muscle activity by measuring these
electrical signals. Clinicians and
researchers have applied the study of EMGs to the fields of neurology, surgical
assessments, functional capacity evaluations, ergonomics and overuse injuries,
and chronic pain evaluations, just to name a few.
In
addition to the extensive EMG analysis options found in the Analog module of
the Ariel Performance Analysis System
(APAS), the Ariel EMG program provides additional
capabilities. The ARIEL EMG software is a Windows based program for calculating the
integral and normalizing the EMG signal in both time and amplitude. An
understanding of the electrophysiology
and the technology of recording is recommended for optimal use of the EMG
program.
Although
a few of EMG’s features appear
complex, they are relatively easy to master once you understand the underlying
concepts. This manual is arranged to
teach you these concepts in a logical order by showing you, in step-by-step
fashion, how to use the EMG
program.
A
few of the new features you will see in EMG version 1.0
1.
EMG Signal Normalization. EMG signals can be normalized in both Time
and Amplitude.
2.
EMG Signal Integration. EMG signals can be integrated using several
parameters.
The
following list provides the basic guidelines for the necessary components of
the EMG program to provide the best possible performance. The software requires a minimum of Microsoft
Windows 95/98 or later and APAS-2000 Revision 1.0 or later (with the
EMG/Analog).
1.
Ariel Performance Analysis System (APAS) software used to collect EMG
data in *.ANA file formats.
Prior
to performing the EMG analysis
process, you should take the time to familiarize yourself with the format and
contents of the various screens listed below:
You
can activate many functions by selecting the icons located on the EMG program tool bar. The tool bar is located near the top of the
window. Icons are pictorial
representations of commands or functions.
You can access the following commands by clicking the appropriate icon.
When
an EMG file is opened, additional windows will be displayed inside the
main window. Multiple windows can be opened simultaneously. The EMG
Title will be displayed at the top of each active Window.
The
status bar provides information about the current EMG analog file. The status bar is located at the bottom of
the EMG window.
The
far left side of the status bar indicates the current status of the EMG
file. This field will usually state READY.
The far right side of the status bar displays the currently selected
analog (*.ANA) file.
1.
Double-click the EMG icon
located in the APAS System window
group. The main EMG window will appear.
The
following steps are recommended for correct operation of the EMG program.
1.
Choose the NEW command from the FILE menu. This will open a new *.EMG document with an empty list of EMG
data sets. A grid with 8 columns
appears to display the active sample list.
2.
Select the ANALOG command
from the FILE menu to specify
an Analog (*.ANA) file for retrieving
data sets. This selection can be
changed at any time.
3.
Click on the NEW button below
the “grid” and select a Save Trial and Channel from the active Analog
file. Select the OK button to enter the selected data set to the active data set
display.
4.
Repeat Step #3
to select all data sets of interest.
5.
Mark
individual entries as either active or inactive by clicking in the 1st
column of the grid. Active channels
will be graphed and displayed for analysis.
If an entry is active, a "=>"
will be displayed in the first column.
If an entry is inactive, the first column will be blank. If the user selects FILE, SAVE AS and there
are disabled channels, the program prompts the user whether or not to save
disabled channels.
6.
Mark an
individual entry as the Maximum Voluntary Contraction (MVC) by clicking the 2nd
column of the grid. The Maximum
Voluntary Contraction channel is the channel where the subject has performed a
maximum contraction. Marking a channel
at the MVC is only required for normalizing using the MVC option.
7.
Mark an
individual entry as the Trigger channel by clicking the 3rd column
of the grid. The Trigger channel is
used in partitioning data. It typically
is not an EMG channels but rather some other signal which helps one partition
the EMG data. An example would be a
switch opening/closing to define an activity of interest.
NEW - This button
is selected to add a save trial from the currently active analog file.
DELETE - This button
is selected to remove a save trial from the analysis table.
ENABLE ALL - This button is selected to
ACTIVATE All the Save Trials in the analysis table.
DISABLE ALL - This button
is selected to INACTIVATE All the Save Trials in the analysis table. Disabled channels will not be graphed.
PARTITION - This button
is selected to Partition the selected entries.
At
this point, the program is ready to Graph the EMG data.
When
sampling EMG activity, it is often useful to analyze specific intervals of the
entire signal. The Partition option
allows the user to partition an EMG signal into smaller intervals for analysis. Multiple curves can be simultaneously
partitioned. The following steps are
recommended for partitioning an EMG signal.
1. Select the
PARTITION button to display the Partition Channel menu.
2. Select the
CHANNELS button to specify which data channels are active during the
partitioning. Individual channels are
selected by clicking in the Status column next to the desired channel. All channels can be activated by selecting
the Select All button. All channels can
be deactivated by selecting the Clear button.
Select OK to proceed.
3. Select the
desired partition by clicking the left mouse button and dragging the cursor to
highlight the desired partition. The
partition will be seen as an alternate color.
4. Select the Add
button to enter the data in the partition list. Repeat step #3 for additional partitions.
5. Select OK to
return to the data entry table. The
partition information will be updated in the table.
Once
the desired trials have been entered into the table, activated and partitioned
(if desired), the data can be graphed utilizing several analysis options.
1. Select the GRAPH
menu to display the available graphing options for the EMG data.
The
EMG command provides several options for graphing and analyzing the
"raw" EMG signal. When this
command is selected, the RAW EMG OPTIONS menu will be displayed.
GENERAL
X-Normalize - Selected to
normalize all selected graphs to the same time scale (X-axis). All the active graphs will be normalized to
the same time scale as the graph with the smallest time period.
AutoScale - Selected to
display the entire graph(s) with maximum resolution. The size of the graph remains constant, regardless of the size of
the display window.
Fit to Scale -
Selected
to display the entire graph regardless of the size of the window. If the window size is adjusted, the graph
will also adjust to fit the new size of the window.
Rectify - Selected to
perform a full-wave rectification on the "raw" EMG signal.
Maximize - Selected to
enlarge the window to the maximum size.
Y-NORMALIZE
None - Selected to
display the graph(s) without Y-Normalization being performed.
MaxPeak - Selected to
normalize all the curves so that all curves will have a peak value for the
envelope equal to the curve which un-normalized had the largest envelope value.
%Mode - Selected to
scale each curve so that the peak value for the envelope curve is 100%.
100% MVC - Selected to
perform the Linear Envelope of this data and normalize the other active
channels to the MVC channel. It is
often desired to normalize to 100% of this "maximum" contraction
value. For example, if the MVC channel
has a peak value (LE) of 4.0mv and 100% normalization has been selected, then
other channels would be normalized so that their peaks would be 4.0 mv.
50% MVC - Selected to
perform the Linear Envelope of this data and normalize the other active
channels to the MVC channel. It is
often desired to normalize to 50% of this "maximum" contraction
value. For example, if the MVC channel
has a peak value (LE) of 4.0mv and 50% normalization has been selected, then
other channels would be normalized so that their peaks would be 2.0 mv.
CURVES
Raw + LE - Selected to
graphically display the Raw data curve as well as the computed Linear Envelope
(LE) curve.
Raw Only - Selected to
graphically display only the Raw data curve.
LE Only - Selected to
graphically display only the computed Linear Envelope curve.
PIXEL MODE
Due
to the high sampling rate of EMG signals, one pixel often corresponds to many
A/D samples. The number of data points
are divided by the available pixels to determine the number of data points
represented by each pixel. Each
"set" of pixels can be represented in various ways.
1st
- Selected
to use the First data point of each group to represent the entire group.
Max - Selected to
use the Maximum data point of each group to represent the entire group.
Avg - Selected to
use the computed Average of all the data point of each group to represent the
entire group.
LE TIME (sec)
This
field is used to enter the time interval for the Linear Envelope (LE). The LE is used to remove rapid signal
fluctuations by averaging over an interval that is longer than the duration of
individual "spikes" or fluctuations.
It is similar in nature to a low-pass analog filter. The longer the time constant, the lower the
cutoff frequency of this filter. Some
experimentation may be necessary, however, a default value of 0.1 seconds will
be displayed.
The
AVG/RMS command provides several options for graphing and analyzing the Average
EMG signal. When this command is
selected, the AVG/RMS GRAPH OPTIONS
menu will be displayed.
GENERAL
X-Normalize - Selected to
normalize all selected graphs to the same time scale (X-axis). All the active graphs will be normalized to
the same time scale as the graph with the smallest time period.
Fit to Scale -
Selected
to display the entire graph regardless of the size of the window. If the window size is adjusted, the graph
will also adjust to fit the new size of the window.
Maximize - Selected to
enlarge the window to the maximum size.
Y-NORMALIZE
None - Selected to
display the graph(s) without Y-Normalization being performed.
MaxPeak - Selected to
normalize all the curves so that all curves will have a peak value for the
envelope equal to the curve which un-normalized had the largest envelope value.
%Mode - Selected to
scale each curve so that the peak value for the envelope curve is 100%.
100% MVC - Selected to
perform the Linear Envelope of this data and normalize the other active
channels to the MVC channel. It is
often desired to normalize to 100% of this "maximum" contraction
value. For example, if the MVC channel
has a peak value (LE) of 4.0mv and 100% normalization has been selected, then
other channels would be normalized so that their peaks would be 4.0 mv.
50% MVC - Selected to
perform the Linear Envelope of this data and normalize the other active
channels to the MVC channel. It is
often desired to normalize to 50% of this "maximum" contraction
value. For example, if the MVC channel
has a peak value (LE) of 4.0mv and 50% normalization has been selected, then
other channels would be normalized so that their peaks would be 2.0 mv.
LE TIME (sec)
This
field is used to enter the time interval for the Linear Envelope (LE). The LE is used to remove rapid signal
fluctuations by averaging over an interval that is longer than the duration of
individual "spikes" or fluctuations.
It is similar in nature to a low-pass analog filter. The longer the time constant, the lower the
cutoff frequency of this filter. Some
experimentation may be necessary, however, a default value of 0.1 seconds will
be displayed.
The
INTEGRAL command is selected to perform one of several types of integration on
the EMG signal. These integration
options produce data curves representing the integrl or area under the input
curve in different formats. When this
command is selected, the INTEGRAL
OPTIONS menu will be displayed.
GENERAL
X-Normalize - Selected to
normalize all selected graphs to the same time scale (X-axis). All the active graphs will be normalized to
the same time scale as the graph with the smallest time period.
AutoScale - Selected to
display the entire graph(s) with maximum resolution. The size of the graph remains constant, regardless of the size of
the display window.
Fit to Scale -
Selected
to display the entire graph regardless of the size of the window. If the window size is adjusted, the graph
will also adjust to fit the new size of the window.
Maximize - Selected to
enlarge the window to the maximum size.
Y-NORMALIZE
None - Selected to
display the graph(s) without Y-Normalization being performed.
MaxPeak - Selected to
normalize all the curves so that all curves will have a peak value for the
envelope equal to the curve which un-normalized had the largest envelope value.
%Mode - Selected to
scale each curve so that the peak value for the envelope curve is 100%.
100% MVC - Selected to
perform the Linear Envelope of this data and normalize the other active
channels to the MVC channel. It is
often desired to normalize to 100% of this "maximum" contraction
value. For example, if the MVC channel
has a peak value (LE) of 4.0mv and 100% normalization has been selected, then
other channels would be normalized so that their peaks would be 4.0 mv.
50% MVC - Selected to
perform the Linear Envelope of this data and normalize the other active
channels to the MVC channel. It is
often desired to normalize to 50% of this "maximum" contraction
value. For example, if the MVC channel
has a peak value (LE) of 4.0mv and 50% normalization has been selected, then
other channels would be normalized so that their peaks would be 2.0 mv.
RESET
Select
one of the following Reset options for integrating the signal.
None - Selected to
perform a summing integral or an integral with "No-reset." The curve value represents the cummulative
integral of the input channel and thus is a monotonically increasing curve.
Time - Selected to
perform a constant frequency resetting integral. The integral curve is cummulative for a specified
"Time" interval, then is reset to zero and begins accumulating
again. This produces a series of peaks
at a constant interval whose amplitude indicates the level of activity of the
EMG signal.
Value - Selected to
perform a constant amplitude resetting integral. The integral curve is cummulative until a specified
"Value" is reached, then is reset to zero and begins accumulating
again. This produces a series of peaks
at a constant amplitude whose frequency indicates the level of activity of the
EMG signal.
RESET TIME (sec)
This
field is used to enter the time interval for the Time Reset option.
RESET VALUE (mv-sec)
This
field is used to enter the value for the Value Reset option.
LE TIME (sec)
This
field is used to enter the time interval for the Linear Envelope (LE). The LE is used to remove rapid signal
fluctuations by averaging over an interval that is longer than the duration of
individual "spikes" or fluctuations.
It is similar in nature to a low-pass analog filter. The longer the time constant, the lower the
cutoff frequency of this filter. Some
experimentation may be necessary, however, a default value of 0.1 seconds will
be displayed.
The
POWER command is selected to perform a power spectrum analysis of the EMG data
signal. This analysis produces a graph
of power as a function of frequency based on a Fourier decomposition of the
analog signal. Power is defined as the
sum of the squares of the Fourier coefficients. Since the EMG signal consists of many component frequencies, this
type of anlysis provides an indication of the dominant frequencies and their
relative amplitudes within the composite signal. When this command is selected, the POWER GRAPH
OPTIONS menu will be displayed.
GENERAL
X-Normalize - Selected to
normalize all selected graphs to the same time scale (X-axis). All the active graphs will be normalized to
the same time scale as the graph with the smallest time period.
AutoScale - Selected to
display the entire graph(s) with maximum resolution. The size of the graph remains constant, regardless of the size of
the display window.
Fit to Scale -
Selected
to display the entire graph regardless of the size of the window. If the window size is adjusted, the graph
will also adjust to fit the new size of the window.
Amplitude - Selected to
perform an Amplitude analysis on the active channels. This analysis produces a graph of Amplitude as a function of
frequency.
Maximize - Selected to
enlarge the window to the maximum size.
Y-NORMALIZE
None - Selected to
display the graph(s) without Y-Normalization being performed.
MaxPeak - Selected to
normalize all the curves so that all curves will have a peak value for the
envelope equal to the curve which un-normalized had the largest envelope value.
%Mode - Selected to
scale each curve so that the peak value for the envelope curve is 100%.
100% MVC - Selected to
perform the Linear Envelope of this data and normalize the other active
channels to the MVC channel. It is
often desired to normalize to 100% of this "maximum" contraction
value. For example, if the MVC channel
has a peak value (LE) of 4.0mv and 100% normalization has been selected, then
other channels would be normalized so that their peaks would be 4.0 mv.
50% MVC - Selected to
perform the Linear Envelope of this data and normalize the other active
channels to the MVC channel. It is
often desired to normalize to 50% of this "maximum" contraction
value. For example, if the MVC channel
has a peak value (LE) of 4.0mv and 50% normalization has been selected, then
other channels would be normalized so that their peaks would be 2.0 mv.
MAX FREQ
Select
the Maximum Frequency for the computation of the power spectrum. Only the power component frequencies below
the maximum frequency will be reported.
This allows the user to scale the power spectrum to the frequency band
most applicable to the signal being studied.
The
largest value for the maximum frequency
that can be detected in a power spectrum analysis is the Nyquist or
"folding frequency" which is one-half the frequency of data
measurement. Be aware that if there are
frequencies in the input signal above the folding frequency, aliasing (high frequency
signals "appearing" as low frequency signals) may occur. To properly interpret a power spectrum
measurement on an analog signal, one must know the true range of frequencies in
the data.
LE TIME (sec)
This
field is used to enter the time interval for the Linear Envelope (LE). The LE is used to remove rapid signal
fluctuations by averaging over an interval that is longer than the duration of
individual "spikes" or fluctuations.
It is similar in nature to a low-pass analog filter. The longer the time constant, the lower the
cutoff frequency of this filter. Some
experimentation may be necessary, however, a default value of 0.1 seconds will
be displayed.
Once
the EMG analysis file has been created, the entire file can be saved as a
project (*.EMG file) for later use. The
SAVE/SAVE AS commands can be used to save all the information that is used to
create the analysis. This includes, MVC
channel, Trigger channel, partitioning information as well as the associated
analog and files. There are two options
for saving the EMG file:
1.
Choose the SAVE command from
the FILE menu. This command will Save the current
information using a sequentially numbered default file name (Emg1.emg, Emg2.emg
etc.) and Save it to the current drive and directory. The *.EMG extension will be added automatically.
OR...
2.
Select the SAVE AS commands
from the FILE menu. The Save As dialog box will appear showing
the current file name, directory, drive and file type. At this point, you can enter the desired
name for the EMG file. Please note that
the file must have the EMG extension.
EMG
files can be created and saved to retain the necessary information for
displaying the EMG analysis. Files can
then be Restored at a later time for comparison and/or analysis. There are two methods to Restore a
previously created EMG file:
1.
Choose the OPEN command from
the File menu. The OPEN
File Dialog box will appear. Select the desired drive, directory and
*.EMG file and click the OK button.
OR...
2.
Select the File Open icon from the EMG Tool Bar. The OPEN File Dialog box will appear.
Select the desired drive, directory and *.EMG file and click the OK button.
The
FONT parameters can be changed by the following process:
1. Select the FONT command from the OPTIONS
menu. You will be presented with a Font
menu of the available options. The
options include Font, Font Style, Size, Effects and Script. Select the desired options with the left
mouse button. Press the OK button to
save the selected choice. Select the
CANCEL button to abort this menu without saving the changes.
The
EMG color scheme can be changed by the following process:
1. Select the COLOR command from the OPTIONS menu. Select the desired color using the mouse.
CREATING A NEW EMG PROJECT
1. Select FILE,
NEW (or the New Document icon in the
Tool Bar) to Open a new *.EMG document.
2. Select FILE, ANALOG to open the desired EMG analog file.
3. Click on the NEW button below the "grid"
and select a Save Trial and Channel from the active Analog file. Select the OK button to enter the selected data set to the active data set
display.
4. Repeat Step #3
to select all data sets of interest.
5. Mark
individual entries as either active or inactive by clicking the cursor in the
1st column of the grid. Active channels
will be graphed and displayed for analysis.
6. Mark an
individual entry as the Maximum Voluntary Contraction (MVC) by clicking the 2nd
column of the grid.
7. Mark an
individual entry as the Trigger channel by clicking the 3rd column
of the grid.
8. You are now
ready to Graph, Export or Save the EMG project.
GRAPHING EMG DATA
1. Select GRAPH,
and the desired Graph type. Available
choices are EMG, AVG/RMS, INTEGRAL and POWER.
2. Specify the
desired Graph options and select OK
to display the graphed data.
3. Repeat Step#1
for desired additional graphs.
EXPORTING EMG DATA
Data
can be exported to a Worksheet file as well as to an ARIEL format Analog file.
WORKSHEET
1. Select EXPORT,
WORKSHEET, NEW to create a new worksheet file. Select EXPORT, WORKSHEET, OPEN to append to an existing worksheet file.
2. Select EXPORT,
WORKSHEET, SAVE to save the desired data to the active worksheet.
3. Enter the desired Export Information and
select OK to proceed.
4. Select EXPORT, WORKSHEET, CLOSE to
close the active worksheet
ANALOG
1. Select EXPORT,
ANALOG, NEW to create a new .ANA file.
Select EXPORT, ANALOG, OPEN to append to an existing Analog (.ANA) file.
2. Select EXPORT,
ANALOG, SAVE to save the desired data to the active Analog file.
3. Enter the desired Trial ID Caption and select
OK to proceed.
4. Select EXPORT, ANALOG, CLOSE to close
the active Analog file.
SAVING AN EMG PROJECT
1. Select FILE, SAVE AS to save the EMG project.
2. Select FILE, EXIT to exit the EMG program.
Listed
below are the various menus for the EMG program. Select the desired menu to see a description of the available
commands for each menu.
New
Selected to open a new *.EMG file for
creating an EMG project.
Open
Select the OPEN command to open an existing
*.EMG file. . When this option is
selected, the Open File dialog box will appear.
Close
Select the CLOSE command to close the
currently open file.
Save
Select the SAVE command to SAVE the current
*.EMG project file. When this option is
selected, the Save File dialog box will appear.
Save As
Selected to SAVE the current file AS
another name.
Analog
Selected to open a previously created ANA
format ANALOG file to be used for the EMG analysis.
Print Preview
Selected to check or examine the
positioning on one or more pages. When
you give the Print Preview command, a new window will be open showing the
document position as it would appear on paper.
To close the Print Preview window, select the Cancel button to go to the
previous mode.
Print
Select the Print command to send the
current file to a printer.
Print Setup
Selected to adjust the printer settings
prior to issuing the PRINT command.
Recent File
Selected to open one of the most RECENT
FILEs that were used. Files are
selected the highlighted file name.
Exit
Selected to EXIT the EMG program and return
to the APAS group in Microsoft Windows program manager.
Undo
Select the UNDO command to retrieve edited
data. The UNDO command reflects the
last change you made, such as Undo Delete or Undo Insert.
Cut
Select the CUT command to remove the
selected item and temporarily copy it to the Windows Clipboard. The items are placed in the clipboard so
that it can be Pasted into another area of the same application or into another
Windows application. To avoid losing
this item, you should Paste it before performing any additional editing.
Copy
Select the COPY command to make a COPY of
the selected item and temporarily copy it to the Windows Clipboard. The items are placed in the clipboard so
that it can be Pasted into another area of the same application or into another
Windows application. To avoid losing
this item, you should Paste it before performing any additional editing
Paste
Select the PASTE command to insert a copy
of the item currently in the Windows clipboard. This item could have been cut or copied from almost any Windows
application.
Toolbar
Selected to display or remove the EMG
Toolbar located at the top of the view window.
This command acts like a toggle switch.
The check mark next to the Toolbar command indicates that the Toolbar
will be visible. Selecting this option
again, will remove the check mark and remove the Toolbar from view.
Status Bar
Selected to display or remove the EMG
Status Bar located at the bottom of the view window. This command acts like a toggle switch. The check mark next to the Status Bar command indicates that the
Status Bar will be visible. Selecting
this option again, will remove the check mark and remove the Status Bar from
view.
EMG
Selected to display information pertaining
to the “raw” EMG signal. When this
option is selected, an additional menu will be presented that allows changing
the display parameters.
Avg/RMS
Selected to display the combined Average
and RMS curves calculated from the “raw” EMG signal. When this option is selected, an additional menu will be
presented that allows changing the display parameters.
Integral
Selected to display the Integral curves
calculated from the “raw” EMG signal.
When this option is selected, an additional menu will be presented that
allows changing the display parameters.
Power
Selected to display the Power spectrum
curves calculated from the “raw” EMG signal.
When this option is selected, an additional menu will be presented that
allows changing the display parameters.
Worksheet
Selected to activate the worksheet option for
data export. This option allows EMG
data to be exported to a worksheet for further data processing.
Analog File
Selected to activate the Analog File option
for data export. This option allows
processed EMG data to be exported to the *.ANA format file and saved as a new
data file.
New
Selected to create a New worksheet/analog
file for data export. When this command
is selected, a menu will be presented to specify the drive, folder and file
name for the worksheet/analog file.
Open
Selected to Open a worksheet/analog file
for data export. When this command is
selected, a menu will be presented to specify the drive, folder and file name
for the worksheet/analog file.
Close
Selected to close the currently open
worksheet/analog file.
Save
Selected to SAVE the selected date to the
specified worksheet/analog file.
Cascade
Selected to arrange all programs that are
window sized in an overlapping CASCADE.
This will not arrange a program that has been minimized to an icon.
Tile
Selected to re-size the program windows to
fit side-by-side on the screen. Since
Windows will include all programs that are window-sized in the tile setup, it
is best to minimize all programs that are not currently being used so it will
not take up space on the screen.
Arrange Icons
Selected to automatically ARRANGE ICONS in
a straight row. The user has no control
over where the icons are placed.
Fonts
Selected to set the Font, style, size and
effects for the displayed graphics.
Colors
Selected to adjust the colors of the
displayed graphs.
Index
Selected to provide an INDEX of Help
related topics.
Using Help
Selected to provide instructions on using
the Help Windows.
About EMG
Provides information about the EMG program